AKSG input reactor
AKSG input reactor
Product description:
◆ Electrical performance and standards:1, to reduce the inverter and DC governor work on other equipmentinterference (harmonic interference, waveform distortion);2, reduce the motor wor…
OnlineOrder
Details


Electrical performance and standards:
1, to reduce the inverter and DC governor work on other equipmentinterference (harmonic interference, waveform distortion);
2, reduce the motor working noise, eddy current loss, reduce the motortemperature rise;
3, protection due to low resistance caused by the peak capacitive current onthe drive rectifier module and related components of the damage (power supplycapacity is greater than 5 times the capacity of the inverter);
4, to improve the power factor of the power supply to reduce the inverter powersupply harmonic current content;
5, reduce the current and voltage waveform distortion rate, improve the qualityof the power supply, smooth inverter output voltage and current waveform,reduce the transient voltage dv / dt impact on the motor insulation system toextend the motor life;
6, input and output reactor installed in the inverter or governor input andoutput. Its main function is to suppress 3 or 5 harmonics into the grid, canreduce the leakage current caused by high and low harmonics to reduce theinterference of peripheral equipment;
7, to limit the abnormal voltage fluctuations and the impact of the gridcurrent, and to suppress the power grid harmonic damage to the inverter.
8, for the load from the main power distribution far, plus the reactor can beextended to the inverter motor to extend the effective distance; reduce thecapacitive current cable to protect the inverter internal power switchingdevices, the power factor to enhance a certain role, And can improve the wholereactive power compensation coefficient and quality.
Technical parameters:
1, rated working voltage: AC380V ~ 1140V (conventional voltage 3
380V, specialto be customized) Rated operating frequency: 50HZ / 60HZ
2, the rated voltage drop: 1% -6% (conventional reactance input 2% output 4%)
3, the working pressure: the core of the winding 3000VAC / 50HZ / 5MA / 60S noarcing no breakdown (factory test humidity <55%
4, insulation resistance: core on the winding 1000VDC ≥ 100M;
5, the working temperature: core <80K (temperature calculation, the coretemperature minus the ambient temperature) Coil winding temperature <95K (DCresistance test method)
6, working noise: ≤ 60dB (1M away from the reactor level test);
7, the implementation of standards: GB19212.1-2008 GB1094.6-2011

Invertersupporting the use of input and output reactor:


Governor inverter power  (KW)

Rated Current      (A)

Input Reactor Model

L*W*H (mm)

Mounting Dimensionmm

Output Reactor Model

L*W*H (mm)

Mounting Dimension (mm)

0.75

2.5

AKSG-0.75KW/5V

140*85*140

75*55Φ6

AKSG-0.75KW/9V

140*85*140

75*55Φ6

1.5

5

AKSG-1.5KW/5V

140*85*140

75*55Φ6

AKSG-1.5KW/9V

140*85*140

75*55Φ6

2.5

7.5

AKSG-2.2KW/5V

140*85*140

75*55Φ6

AKSG-2.2KW/9V

140*85*140

75*55Φ6

3.7

10

AKSG-3.7KW/5V

140*85*140

75*55Φ6

AKSG-3.7KW/9V

140*85*140

75*55Φ6

5.5

15

AKSG-5.5KW/5V

140*85*140

75*55Φ6

AKSG-5.5KW/9V

140*85*140

75*55Φ6

7.5

20

AKSG-7.5KW/5V

175*130*140

82*75Φ6

AKSG-7.5KW/9V

140*85*140

75*55Φ6

11

30

AKSG-11KW/5V

175*130*140

82*75Φ6

AKSG-11KW/9V

210*165*170

110*85Φ8

15

40

AKSG-15KW/5V

210*120*190

110*70Φ8

AKSG-15KW/9V

210*165*170

110*85Φ8

18.5

50

AKSG-18.5KW/5V

210*120*190

110*70Φ8

AKSG-18.5KW/9V

210*165*170

110*85Φ8

22

60

AKSG-22KW/5V

210*165*170

110*85Φ8

AKSG-22KW/9V

210*165*170

110*85Φ8

30

80

AKSG-30KW/5V

210*165*170

110*85Φ8

AKSG-30KW/9V

270*190*230

155*100Φ10

37

110

AKSG-37KW/5V

210*165*170

110*85Φ8

AKSG-37KW/9V

270*190*230

155*100Φ10

45

125

AKSG-45KW/5V

210*165*170

110*85Φ8

AKSG-45KW/9V

270*190*230

155*100Φ10

55

150

AKSG-55KW/5V

270*170*220

155*85Φ10

AKSG-55KW/9V

290*200*230

170*115Φ10

75

200

AKSG-75KW/5V

290*190**255

170*85Φ10

AKSG-75KW/9V

300*230*230

173*135Φ10

93

250

AKSG-93KW/5V

290*190*230

170*105Φ10

AKSG-93KW/9V

330*230*230

190*130Φ10

110

275

AKSG-110KW/5V

290*190*230

170*105Φ10

AKSG-110KW/9V

330*230*230

190*130Φ10

132

330

AKSG-132KW/5V

320*240*230

193*130Φ10

AKSG-132KW/9V

340*230*230

212*130Φ10

160

450

AKSG-160KW/5V

330*210*290

193*130Φ10

AKSG-160KW/9V

330*220*290

193*140Φ10

185

500

AKSG-185KW/5V

330*210*290

193*130Φ10

AKSG-185KW/9V

330*220*290

193*140Φ10

200

510

AKSG-200KW/5V

330*210*290

193*130Φ10

AKSG-200KW/9V

330*220*290

193*140Φ10

220

540

AKSG-220KW/5V

330*210*290

193*130Φ10

AKSG-220KW/9V

330*220*290

193*140Φ10

250

625

AKSG-250KW/5V

330*220*290

193*140Φ10

AKSG-250KW/9V

350*280*290

193*150Φ10

315

800

AKSG-315KW/5V

330*240*290

193*150Φ10

AKSG-315KW/9V

350*280*290

193*150Φ10

375

1000

AKSG-375KW/5V

350*280*290

193*150Φ10

AKSG-375KW/9V

400*300*350

240*200Φ10

400

1100

AKSG-400KW/5V

350*280*290

193*150Φ10

AKSG-400KW/9V

400*300*350

240*200Φ10

600

1600

AKSG-600KW/5V

420*380*560

220*185Φ10

AKSG-600KW/9V

420*380*560

220*185Φ10


Product Features:


Iproduced the AKSG series inverter, DC governor for the input and outputreactor, the use of imported silicon steel and high-quality wire, after ascientific process
High linearity, high overload current capacity, small size, stable performance,low temperature rise, low noise, low loss and other characteristics. Availablewith Siemens ABB, Panasonic, Yasukawa, Pu Chuan, Danfoss, Fuji, Continental,LG, Omron, Hyundai, Schneider, Lenz Emerson, Kangwo and other domestic andforeign brands
Frequency converter supporting for wind power, water conservancy, lifting,metallurgical automation and control industries.
Ordering Information (order must specify the following)
1. Adapt the inverter or adjust the power (KW)
2. Inverter rated power supply voltage: V or more for the Division of thestandard product parameters for reference, other parameters and size can becustomized
3. Used in the line end or outlet;
4. Can also be based on the maximum frequency converter
For the current and inductance, the recommended selection;
5. Can also be based on the rated supply voltage of the inverter
And reactance rate, the recommended selection;
6, whether there is a special size requirements;
7. Delivery cycle.


 


??

Big customer department: +86 15950901698 Mr dan  service: +86 13773168522 Joe S
Dealer Department: +86 13862612906  Mr Zhang  service: +86 15062616309 Lv S
Company Phone: +86 512 57908556/57906926 Company Fax: +86 512 57908559
Website: sanyuan04.cn www.kssaio.cn E-mail: dan@kssaio.com
Address: No.225, Penglang Datong Road, Economic Development Zone, Kunshan City, Jiangsu Province, China


Copyright: Kunshan Saio Electric Manufacture Co., Ltd.  TS:KSGC  Su ICP14036040-4
  • Public number
  • Official wap
Links: 阿里巴巴  百度  慧聰網  賽歐內站 
Online x
分享按鈕