性按摩AAAAAAA片,又色又污又爽又黄的网站,欧美三级视频在线播放,无码中文三级在线观看,久久无码鲁丝片午夜精品,色色老网站

Welcome to Kunshan Saio Electric Manufacturing Co., Ltd. Website!

WapChineseEnglishHomepageFavorites

Big customer department: +86 15950901698 Manager dan
Exclusive customer service: +86 13773168522 Joe S
Dealer Department: +86 13862612906 Manager Zhang
Exclusive customer service: +86 15062616309 Lu S
Sheet metal Department: +86 15366271877 Manager  Li
Tel: +86 512 57908556 57906926
Fax: +86 512 57908559
DCL DC reactor (for inverter)
DCL DC reactor (for inverter)
Product description:
◆ Product inBK/JBK Single Isolation TransformerSeries is used of electromagnetic induction principle and developed accordingto the latest CNC servo system parameter. These products ar…
OnlineOrder
Details

◆ Product 
in BK/JBK Single Isolation TransformerSeries is used of electromagnetic induction principle and developed accordingto the latest CNC servo system parameter.
These products are absorbed merits ofsame kinds of products at domestic and aboard, with constant improvement andfurther by Saio Electric over years experiences. Used advanced technology andpreciseness design to proceed on manufacturing, and select foreign advancedterminals, with excellent performance、 work reliable、low energy consumption、small volume、Wiring Safety、extensive applicability, extracharacteristics, it is an ideal voltage power supply.
Apply to 50~60Hz,Rated supply voltage ≤1000V at AC Circult , Serve as Control Powersupply for Machine Tool and mechanical Equipment, as power
supply of operating illumination andsignal lamp ; Also be a mini-type motive power.

◆The function of single phase isolation transformer

The main function of single phaseisolation transformer : make primary side and secondary side electric insulationcompletely, also isolates the loop.
In addition, use high frequencydissipation of iron core, suppress high frequency clutter afferent controlloop. Use the insulated transformer to levitate the ground twice, only can be used for less powersupply 、short circuit occasion. Meanwhile, thesecondary side of system no voltage to ground ! play a role of isolation dangerous voltage.

◆ Installment environment 
1、Altitude≤2500m;
2、Ambient air temperature is not over 40℃,no lower than -25℃;
3、Relative air humidity: The average maximum relativehumidity of the wettest month is 90%;
4、No strenuous vibrationand impulsive place;
5、The place is themedium of no explosion hazard, no enough corroding metal and destroy insulationgas and electric conduction dust.
6、The place is noinvasive by rain and snow.
7、Waveform of supply voltage is similar to sine wave.

◆ Structural feature
This product comply to JB/T9646 and relativestandards, iron core of BK model is Shell type , which made of by silicon steelsheet with dashing, cutting, convoluting.Iron Core of BKC Model is heart type,which made of by silicon steel sheet with rolling C shape.coils of BK、JBKseries are multiple cylindrical winding ,The primary, secondary coils are woundseparately. Usually except primary windings, There are two general secondarywindings. One is "light winding" supply voltage for local lighting ; Anotheris "control winding" supply the machine to control the voltage neededfor the electrical apparatus. The same transformer is "controlled"and "illuminated" by two windings, the secondary winding is separatedwinding of independent winding. The terminal of light winding is grounded, Someof them also use the way to draw the joint , to extract 6.3V Voltage supplysignal lamp from secondary control winding.

◆ Attention
1. Before purchasing, estimate the total capacity of theappliances you use, and select a transformer with considerable capacity toensure that the transformer is not burned at instantaneous starting.
2. When you use a multiple winding(multiple control voltage) transformer, clarify the capacity allocation of thewinding and remain the residual amount so as not to burn the transformer.
3. Before installation, you shouldcarefully check whether the data listed in the nameplate is in line with yourrequirements. After the confirmation is correct, the use can be installed.
4. Electricity work, transformer coreand coil will be fever, but the temperature rise of less than 80 ℃) belongs tothe normal phenomenon, if the temperatureover 80 ℃, even smoking, should cutoff the power switch, to recheck electric capacity you are using.
5. During transportation, avoid collision as much as possible. Do not sufferfrom moisture. When used, please pay attention to maintenance to protecttransformer service life.

◆ Order Instruction
The below points must be proposed whenordering
1. phase Number(singleor three-phase)
2. Product Model 
3. Rated Capacity(power) 
4. input and output voltage(primary、secondary voltage) 
5. If you output multiple groups, pleasespecify a capacity allocation list. 
6. with master carton or not? 
7. if it is specific technicalrequirements

◆ Product parameter list
Product model see the product summarypage of the appearance and selection instructions
Equipment capacity:50VA-200KVA(1KVA≠1KW,1KVA≈0.8KW)
Phase number:2∮2W 
Input voltage: 110V 200V 220V 240V 380V 415V 440V 460V 480V 660V(specialcan be customized)
Output voltage: 6V 12V 24V 36V 48V 110V 120V 190V 200V 208V 220V380V 415V 460V 480V(special can be customized)
Use efficiency:≥98%
Voltage fluctuation rate:≤±1% (related to the input voltage standard value)
Insulation class: H level
Compression strength: 3000V silent wear (one minute)
Noise level <60db (80CM leveling distance test)
Cooling type :Dry type is self-cooling or forced cooling fan

◆ Dimension parameter list
Single phase isolation transformer(BK/JBK Series)


 

Item NameItem ModelCapacity(INPUT)(OUTPUT)Dimension    mmInstallation dimension   mmWeight kg
(VA)(W)Input voltage
V
Input current
380V
380V
wiring
mm2
Output voltage
V
220V
output current
A
200V
output current
A
(220V)
wiring
mm2
(L*W*H)(L*W)
Single phaseBK-50VA5040380V


special   can      be customized
0.1 0.5220V

200V


special  can      be customized
0.2 0.2 0.590*80*9565*600.8
Single phaseBK-100VA100800.2 0.50.4 0.4 0.590*90*11066*641.8
Single phaseBK-160VA1601280.3 0.50.6 0.6 0.5120*110*11085*752.8
Single phaseBK-200VA2001600.4 0.50.7 0.8 0.5120*115*11085*853
Single phaseBK-250VA2502000.5 0.50.9 1.0 0.5130*130*14085*954
Single phaseBK-300VA3002400.6 0.51.1 1.2 0.5138*138*140100*924.5
Single phaseBK-400VA4003200.8 0.51.5 1.6 0.5138*138*140100*925
Single phaseBK-500VA5004001.1 0.51.8 2.0 0.5140*130*150112*805.3
Single phaseBK-600VA6004801.3 0.52.2 2.4 0.5140*140*150112*906.2
Single phaseBK-750VA7506001.6 0.52.7 3.0 0.5150*140*150112*1007.3
Single phaseBK-800VA8006401.7 0.52.9 3.2 0.5150*140*150

112*100

7.8

Single phase

BK-1KVA

1000

800

2.1 

0.5

3.6 

4.0 

0.5

160*160*150

128*105

9.4

Single phase

BK-1.5KVA

1500

1200

3.2 

0.5

5.4 

6.0 

0.5

180*160*165

128*128

11.8

Single phase

BK-2KVA

2000

1600

4.2 

0.5

7.3 

8.0 

1

190*170*185

136*132

16.2

Single phase

BK-2.5KVA

2500

2000

5.3 

0.5

9.1 

10.0 

1

190*170*185

136*132

17

Single phase

BK-3KVA

3000

2400

6.3 

0.5

10.9 

12.0 

1

190*195*205

155*125

18.5

Single phase

BK-3.5KVA

3500

2800

7.4 

1

12.7 

14.0 

1.5

190*195*205

155*125

19

Single phase

BK-4KVA

4000

3200

8.4 

1

14.5 

16.0 

2.5

300*190*200

175*115

20

Single phase

BK-5KVA

5000

4000

10.5 

1

18.2 

20.0 

2.5

300*200*200

175*115

21.5

Single phase

BK-6KVA

6000

4800

12.6 

1.5

21.8 

24.0 

4

300*210*200

175*135

23

Single phase

BK-6.5KVA

6500

5200

13.7 

1.5

23.6 

26.0 

4

300*210*200

175*135

25

Single phase

BK-7KVA

7000

5600

14.7 

2.5

25.4 

28.0 

4

340*210*250

200*220

38.5

Single phase

BK-7.5KVA

7500

6000

15.8 

2.5

27.2 

30.0 

4

340*210*250

200*220

40

Single phase

BK-10KVA

10000

8000

21.0 

2.5

36.3 

40.0 

6

370*250*250

225*260

52

Single phase

BK-12KVA

12000

9600

25.2 

4

43.6 

48.0 

10

370*250*250

225*260

58

Big customer department: +86 15950901698 Mr dan  service: +86 13773168522 Joe S
Dealer Department: +86 13862612906  Mr Zhang  service: +86 15062616309 Lv S
Company Phone: +86 512 57908556/57906926 Company Fax: +86 512 57908559
Website: sanyuan04.cn www.kssaio.cn E-mail: dan@kssaio.com
Address: No.225, Penglang Datong Road, Economic Development Zone, Kunshan City, Jiangsu Province, China


Copyright: Kunshan Saio Electric Manufacture Co., Ltd.  TS:KSGC  Su ICP14036040-4
  • Public number
  • Official wap
Online x
分享按鈕